Padde ES200 Series Electric Strike

Description

The ES200 series electric strikes are high security products manufactured from solid stainless steel and designed for use with all access control systems. The strikes are suitable for use with hinged doors which require either fire or security control as part of a building management system.

These strikes are flexible and can be changed from fail safe to fail secure, mounted on the left or right hand side of the door and are available in 12 or 24Vdc.

They offer a strong, dependable and long-lasting electric strike solution.

Key Features

  • Fail safe/fail secure changeable on site
  • High security
  • 4 Hour fire rating
  • 850kg holding force
  • 1 million cycles endurance rating
  • Cast stainless steel body
  • Stainless steel locking pins
  • Low Current consumption - Max 175mA @12Vdc
  • Mounting kit supplied as standard
  • Australian designed and made
  • Tricare 5 Year Warranty

Applications

  • High traffic areas
  • Fire rated door sets
  • Open in/open out doors
  • Suitable for use with all access control systems

Standards and Compliance

  • S3 (Security) Australian Lock Standard (AS4145.2.1993)
  • D3 (Durability) Australian Lock Standard (AS4145.2.1993)
  • BS 5872 Approved
  • Successfully fire rated up to 4hrs on fire door assemblies in accordance with AS1905.1. 2005 (Part 1: Fire resistant door sets)
  • Approved to UL1034 (highest level)
  • CE Approved
  • C-Tick Certified

Specification

Voltage
12 or 24Vdc

Current
175 mA @ 12Vdc - 88 mA @ 24Vdc

Solenoids
Solenoids are rated for continuous use

Monitoring
None

Holding Force
850kg Static Strength Rating

Endurance
Cycle tested to 1,000,000 operations

Latch
Suitable for 15mm latch bolt with 3mm door gap

Environment
Operational temperature range -20°C to +60°C

Body
Solid Stainless Steel Construction

Keeper
Stainless Steel

Specification Statement
The strike should be constructed of solid stainless steel, have a minimum holding force of 850kg and have an endurance rating of 1 million cycles. The one strike must be changeable from fail safe to fail secure on site where required. The strike should not consume current greater than 175mA at 12Vdc and have a solenoid rated for continuous use. Certifications must include CE, C-Tick and 4 hr fire rating.

_________________________________________________________

Ordering Information

100201-000
12V Fail Safe Electric Strike

100201-010
12V Fail Safe Electric Strike with No Extension Lip

100201-020
12V Fail Safe Electric Strike with Extension Lip Holes

100202-000
12V Fail Secure Electric Strike

100202-010
12V Fail Secure Electric Strike with No Extension Lip

100203-000
24V Fail Safe Electric Strike

100204-000
24V Fail Secure Electric Strike

Downloads