The ES2000 series electric strikes are fully monitored high
security products manufactured from solid stainless steel and
designed for use with all access control systems. The strikes are
suitable for use with hinged doors which require either fire or
security control as part of a building management system.
These strikes are flexible and can be changed from fail safe to
fail secure, mounted on the left or right hand side of the door and
are available in 12 or 24Vdc.
They offer a strong, dependable and long-lasting electric strike
solution with a 850kg holding force and endurance rating of 1
million cycles.
Key Features
- Fully monitored - strike locked and door latched
- Fail safe/fail secure changeable on site
- High security
- 4 Hour fire rating
- 850kg holding force
- 1 million cycles endurance rating
- Cast stainless steel body
- Stainless steel locking pins
- SCEC Endorsed
- Low Current consumption - Max 175ma @12Vdc
- Solenoid rated for continuous use
- Mounting kit supplied as standard
- Australian designed and made
- Tricare 5 Year Warranty
Applications
- High traffic areas
- Fire rated door sets
- Open in/open out doors
- Suitable for use with all access control systems
Standards and Compliance
- S3 (Security) Australian Lock Standard (AS4145.2.1993)
- D3 (Durability) Australian Lock Standard (AS4145.2.1993)
- BS 5872 Approved
- Successfully fire rated up to 4hrs on fire door assemblies in
accordance with AS1905.1. 2005 (Part 1: Fire resistant door
sets)
- Approved to UL1034 (highest level)
- CE Approved
- C-Tick Certified
- SCEC endorsed for secure areas
Voltage
12 or 24Vdc
Current
175 mA @ 12Vdc - 88 mA @ 24Vdc
Solenoids
Solenoids are rated for continuous use
Monitoring
Solenoid Monitor - 1 amp NO/NC microswitch
Door/Latch Monitor - 1 amp NO/NC microswitch
Holding Force
850kg Static Strength Rating
Endurance
Cycle tested to 1,000,000 operations
Latch
Suitable for 15mm latch bolt with 3mm door gap
Environment
Operational temperature range - 20°C to +60°C
Body
Solid Stainless Steel Construction
Keeper
Stainless Steel
Specification Statement
The strike should be constructed of solid stainless steel, have a
minimum holding force of 850kg and have an endurance rating of 1
million cycles. Monitoring must include independent door / latch
& solenoid monitoring. The one strike must be changeable from
fail safe to fail secure on site where required. The strike should
not consume current greater than 175mA at 12Vdc and have a solenoid
rated for continuous use. Certifications must include CE, C-Tick
and 4 hr fire rating.
_________________________________________________________
Ordering Information
102001-000
12V Fail Safe Electric Strike
102001-010
12V Fail Safe Electric Strike with no Extension Lip
102001-020
12V Fail Safe with 8mm Extension Lip
102001-060
12V Fail Safe with Extension Lip Holes
102002-000
12V Fail Secure Electric Strike
102001-900
12V Fail Safe Electric Strike - Replacement for Padde
MKV1
102003-000
24V Fail Safe Electric Strike
102003-060
24V Fail Safe with Extension Lip Holes
102003-900
24V Fail Safe - Replacement for Padde MKV1
102004-000
24V Fail Secure Electric Strike