The ES9000 has been designed to suit the harshest commercial
environments, and has the unique feature of the ability to operate
with up to 25kg of pre-load pressure on the keeper. Pre-load is a
common condition that is caused by pulling on a door before it
unlocks, the weight of warped or drooping doors, seals on fire
doors, or by differential air pressure created when heating and
cooling systems are in use.
Standard features include multi voltage 10 - 30Vdc and field
changeable settings from fail safe to fail secure.
Built to last, this is a premium locking solution that has been
tested in excess of 2 million cycles and boasts unique features
like no other available on the market today.
Key Features
- Operates under pre load up to 25kg
- Easy field selectable fail safe/fail secure
- Multi voltage 10-30Vdc
- 1300kg holding force
- 2.5 million cycles endurance rating
- Latch keeper is significantly quieter in operation
- Weather resistant
- Mounting tabs as standard
- Non handed
- Australian designed and made
- Tricare® 5 Year Warranty
Applications
- High traffic areas
- Doors subjected to side load (pre load)
- Fire rated door sets
- Open in/open out doors
- Suitable for use with all access control systems
Standards and Compliance
- S3 (Security) Australian Lock Standard (AS4145.2.1993)
- D3 (Durability) Australian Lock Standard (AS4145.2.1993)
- Successfully fire rated up to 4hrs on fire door assemblies in
accordance with AS1905.1. 2005 (Part 1: Fire resistant door
sets)
- CE Approved
- C-Tick Certified
Voltage
10 - 30Vdc
Current
250mA @12Vdc - 130mA @24Vdc
Solenoids
Solenoid rated for continuous use
Electrical protection
Polarity and back EMF protected
Monitoring
Solenoid Monitor - 1 amp NO/NC microswitch
Door / Latch Monitor - 1 amp NO/NC microswitch
Holding force
1300kg static strength rating
Endurance
1,200,000 cycles endurance rating @ 25kg pre-load
2,500,000 cycles general durability without pre-load conditions
Latching
Suitable for 15mm latch with 3mm door gap
Environment
Operational temperature range - 20C to +60C
Body
Solid Stainless Steel Construction
Keeper
Stainless Steel
Specification Statement
The electric strike should be fully monitored and have
independent door / latch and solenoid monitor switches. Holding
force for the strike should be not less than 1300kg.
Where Power to Lock and Power to Open functions may be required
in the same building, a single electric strike should be
interchangeable from either fail safe or fail secure from the rear
of the strike.
The electric strike should not consume current greater than
250mA @ 12Vdc and have a solenoid rated for continuous use. A fire
rating not less than 4 hours is required where applicable. The
strike must be capable of operating with up to 25kg of pre-load
pressure applied to the keeper, be tested to 2.5 million operations
and carry a minimum warranty of 5 years.
_________________________________________________________
Ordering Information
109001-000
ES9000 Pre - Load Multi Function Strike
109001-010
ES9000 Pre - Load Multi Function Strike - No Extension
Lip
109001-020
ES9000 Pre - Load Multi Function Strike - 8mm Extension Lip
109001-060
ES9000 Pre - Load Multi Function Strike - with Extension Lip
Holes
Note: All ES9000 series electric strikes are supplied in
Fail Safe configuration.